Sign In | Join Free | My carsrow.com |
|
Brand Name : LEADKIN
Model Number : LK-K
Certification : ISO9001, IATF16949, CE
Place of Origin : NINGBO CHINA
MOQ : 50M
Price : negotiation
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1,000,000M/year
Delivery Time : 2-7 working days
Packaging Details : 70*70*8cm Carton
Core : 2,3,4,6
Insulation : MgO
Warranty : 1 Year
Temperature Range : 200℃-1000℃
Accuracy : Class I、II、III
Outside Dia : 0.5-12.7mm
Package : Carton. Pallet
Function : temperature test
Cable Length : 1-5m or Customized
Thermocouple Type : K/N/E/J/T/S/R/B
Type: K/N/E/J/T/S/R/B
Place of Origin: Zhejiang, China (Mainland)
Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
Core number: 2,3,4,6
Inorganic mineral insulating lead material: Ni, Cu
Insulator: 99.6% high purity MgO
Certificate:ISO9001, IATF16949, CE
Application: connecting with thermocouple and instrument machine
Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu
Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0
Product Name | Code | Type | Shaeth Material | Outside Dia. | Temperature |
NiCr-NiSi /NiCr-NiAl | KK | K | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCrSi-NiSi | NK | N | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCr-Konstantan | EK | E | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Fe-Konstantan | JK | J | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Cu-Konstantan | TK | T | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
RhPt10-Ph | SK | S | Inconel600 | 6.0-12.7 | 1100 |
Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.
Type | Class I | Class II | ||
Accuracy | Temp.Range | Accuracy | Temp.Range | |
K | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
N | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
E | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
J | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
T | ±0.5℃ | -40~125℃ | ±1.0℃ | -40~125℃ |
±0.4% | 125℃-350℃ | ±0.75% | 125℃-350℃ | |
S | 0-1100℃ | ±1.0℃ | 0-1100℃ | ±1.5℃ |
Mineral Insulated Metal Sheathed Cable for Thermocouple and Instrument Machine Connection
Overview: Mineral Insulated Metal Sheathed (MI) cables are a type of high-performance cable specifically designed for use in harsh environments and high-temperature applications. They are particularly well-suited for thermocouple connections and the integration of instrumentation in various industrial settings due to their durability, reliability, and excellent thermal conductivity.
Key Features:
Construction:
Metal Sheath: Typically made of stainless steel, copper, or other alloys, providing robust mechanical protection against environmental stressors such as moisture, chemicals, and physical impacts.
Mineral Insulation: The insulation is usually composed of magnesium oxide (MgO) powder, which offers excellent dielectric properties and thermal conductivity, critical for accurate temperature measurement.
Conductors: Usually made of thermoelectric materials (e.g., copper, constantan, or other alloys) that form the thermocouple junction or connect other instrumentation.
Performance:
High Temperature Resistance: MI cables can withstand extreme temperatures (up to 1000°C or higher), making them ideal for applications in furnaces, heat exchangers, and other high-heat environments.
Low Thermal Drift: The use of inorganic insulation minimizes thermal drift, ensuring stable and accurate temperature readings.
Electrical Isolation: The MgO insulation provides excellent electrical isolation, reducing noise and improving the accuracy of temperature measurements.
Advantages:
Durability: The robust metal sheath protects against physical damage, making MI cables suitable for use in rugged industrial environments.
Corrosion Resistance: Metal sheaths, particularly stainless steel, offer excellent resistance to corrosion, extending the lifespan of the cable.
Versatility: MI cables can be used for various thermocouple types (e.g., Type K, J, T, etc.) and can be adapted for different instrumentation applications.
Moisture and Chemical Resistance: The design protects against moisture ingress and exposure to chemicals, ensuring reliable performance in harsh conditions.
We add heat shrink tubing and plastic film to make sure high insulated resistance.
Except marking notes, we also have pass card and test report for every coil cable.
We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.
1. Accurate quotation.
2. Confirm the price, trade term, lead time, payment term etc.
3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.
4. Customer arranges the payment for deposit and sends us bank slip.
5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.
6. End Production-Mass production products photos.
7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.
8. The order is finished perfectly when you receive the goods and get satisfied with them .
9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .
1.What are the advantages of using thermocouples?
Wide temperature range.
Fast response time.
Simple and rugged design.
Relatively inexpensive.
Can be used in various environments, including extreme conditions.
2.What are the disadvantages of thermocouples?
Non-linear output, requiring calibration.
Accuracy may be lower than other temperature sensors (like RTDs).
Requires reference junction compensation for precise measurements.
Susceptible to electromagnetic interference.
![]() |
Mineral Insulated Metal Sheathed Cable for Thermocouple and Instrument Machine Connection Images |